Pond & pool heaters
Here you will find heating systems for koi ponds, garden ponds and pools: de-icers that keep one spot of the water surface open in winter, inline pond heaters with thermostat for installation in the filter circuit, inverter heat pumps for efficient heating of larger water volumes, and heating cables.
The choice depends mainly on your goal. If the pond only needs to stay free of ice in winter, a de-icer is enough. If you want to keep the water temperature stable or extend the season in spring and autumn, you need an inline heater or a heat pump whose output matches the pond volume and location.
Frequently Asked Questions
What heating output do I need for my koi pond?
For inline pond heaters, the manufacturer states an upper limit of around 1 kW per 10,000 litres, i.e. roughly 1 kW up to 10,000 litres and 3 kW up to 30,000 litres. Physically, it takes around 1.16 kWh to heat 1,000 litres of water by 1 °C. Open, shallow or wind-exposed ponds lose considerably more heat and need correspondingly more output.
How is an inline pond heater connected?
The heater is integrated into the filter circuit using hose or PVC pipe and installed outside the pond, protected from splashing water. It needs a constant water flow and must never run dry, so always unplug it when cleaning the filter. 3 kW models require a 400-volt connection.
Does a heat pump also work in sub-zero temperatures?
Yes, depending on the version, our models operate down to −10 °C or −20 °C air temperature and have an automatic defrost function. However, heating output and efficiency drop noticeably the colder the air gets. For winter use, the heat pump should therefore be selected based on its performance at low temperatures.
How much electricity does a pond heater use?
An electric pond heater converts 1 kWh of electricity into around 1 kWh of heat, while a heat pump delivers several times that depending on the air temperature. Consumption is, however, mainly determined by the desired temperature, the water surface area, wind and whether the pond is covered. Stabilising rather than heating up saves the most energy.
Why heating a koi pond can make sense
Koi are cold-blooded: the water temperature determines their metabolism, appetite and how well their immune system works. Below around 10 °C koi hardly eat; below about 4 °C they retreat to the deepest zone of the pond and remain largely still. The problem is less the low temperature itself than strong fluctuations and long transition phases in which the immune system works slowly while pathogens are already active.
In winter, the aim of a pond heater is therefore a stable temperature, not the warmest possible water. Heated koi ponds are often kept at around 10 to 15 °C in winter, frequently around 12 °C, because the immune system works considerably more slowly below that. Alternatively, the heater can be used only in spring and autumn to shorten the transition phases.
De-icers: gas exchange rather than heating
A de-icer such as the Schego pond heater with 300 or 600 watts is a heating rod positioned at the water surface with a float. Even in hard frost, it keeps one spot of the ice open so that digester gases can escape and oxygen can be absorbed. The size of the open area depends on the wattage and outside temperature, not on the size of the pond.
A de-icer barely warms the pond itself. It is suited to ponds with a natural winter rest that are deep enough for the koi to overwinter in the warmer bottom zone.
Inline pond heaters with thermostat
Inline pond heaters such as the Aqua Forte Profi heaters or the Elecro Cygnet are installed outside the pond in the filter circuit. The water flows through the unit, is warmed by a stainless steel or titanium heating element and returned to the pond. You set the target temperature via the thermostat, while overheating protection or a flow switch turns the unit off if there is no flow.
These heaters are relatively inexpensive to buy and quick to install, but in operation they use one kilowatt-hour of electricity per kilowatt-hour of heat. They are particularly suitable for small to medium-sized koi ponds, for targeted stabilisation during cold spells, or as a supplement to a heat pump. A minimum flow from the and installation after the are important so that the heating element does not get dirty.
Heat pumps for koi ponds and pools
An inverter heat pump extracts heat from the ambient air and transfers it to the water via a titanium heat exchanger. The AquaForte Mr. Silence and Mr. Titan models adjust their output continuously and can be controlled via app. The Mr. Silence is offered as a pond and pool heat pump, while the Mr. Titan is designed by the manufacturer for pools and can also cool the water. Under ideal conditions with 27 °C air and water temperature, they deliver several times the energy used as heat. At air temperatures around 0 °C, this factor generally falls to about 3 to 4 for air-to-water heat pumps, which is still clearly more efficient than a purely electric heater.
Heat pumps have a higher purchase price and need a location with free air circulation. They are worthwhile above all for larger koi ponds, swimming ponds and pools that need to be kept at a stable temperature over a longer period. During very cold spells, an additional inline heater can cover peak demand.
Heating cable: flexible warmth along the pond contour
The self-regulating heating cable is laid along the contour of the pond and controlled to within 1 °C by a digital controller. Thanks to its self-regulating characteristic, it does not overheat even where the cable overlaps. The controller also limits the system’s energy consumption.
Calculating the right output
Physics helps with a first estimate: heating 1,000 litres of water by 1 °C takes around 1.16 kWh. A 20,000-litre koi pond that is to be warmed from 6 to 10 °C therefore needs about 93 kWh of heat. A 2 kW heater would need around 46 hours for this, without heat losses. In practice, the pond is constantly losing heat through the surface, walls and filter circuit at the same time.
The manufacturer’s figures for maximum pond size are therefore upper limits for fairly sheltered ponds. With a large water surface, windy location, shallow depth or no cover, it is better to choose the next size up or combine two systems.
Retaining heat instead of reheating
Most heat is lost through the water surface, through evaporation, wind and radiation. A cover from the category noticeably reduces the energy demand of any heater. Insulated pipes, a sheltered location and a reliable thermometer to keep an eye on the actual water temperature are just as helpful.
Install and test the heater in autumn, before the first frosty nights. Suitable products for this preparation can be found under .